Siemens SINAMICS DCM Operating Instructions Manual page 361

Dc converter
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Commissioning in STARTER
Slave-to-slave communication is configured in HWConfig and is simply an extension of an
existing telegram. Telegrams can be extended in STARTER (e.g. p0922 = 999).
Figure 10-14 Configuring the slave-to-slave communication links in STARTER
In order to terminate the configuration of slave-to-slave communication for the DOs, the
telegram data of the DOs in STARTER must be matched to those in the HW Config and
must be extended. The configuration is made centrally via the configuration of the respective
CU.
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
Descriptions of functions
10.2 PROFIBUS
359