Additional system components
7.3 Terminal Module TM15
Terminal type
X520, X521, X522
Terminal type
Connectable conductor
cross-section
Stripped length
Tool
X524
Terminal type
Connectable conductor
cross-section
Stripped length
Tool
7.3.3.2

X500 and X501 DRIVE-CLiQ interface

Table 7- 17
DRIVE-CLiQ interfaces X500 and X501
Pin
1
2
3
4
5
6
7
8
A
B
Blanking plate for DRIVE-CLiQ interfaces included in the scope of delivery;
blanking plate (50 pieces) Order number: 6SL3066-4CA00-0AA0
194
Spring-loaded terminal
Rigid/flexible
Flexible, with end sleeve without plastic sleeve
AWG / kcmil
8 mm
0.4 × 2.0 mm screwdriver
Spring-loaded terminal
Flexible
8 ... 9 mm
0.4 × 2.0 mm screwdriver
Signal name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
GND (0 V)
Technical specifications
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
0.14 mm
... 0.5 mm
2
2
0.25 mm
... 0.5 mm
2
2
26 ... 20
0.08 mm
... 2.5 mm
2
2
SINAMICS DCM DC Converter