Jogging; Increase Setpoint/Decrease Setpoint - Siemens SINAMICS DCM Operating Instructions Manual

Dc converter
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

9.3.7.4

Jogging

Settings: Menu – Commissioning/Service – AOP settings – Control settings
JOG key active (factory setting: No)
● Yes: In "LOCAL" mode, the JOG key is active in the state "Ready for Switching On" (not
● No: The JOG key is not active.
See also function diagram 3125 in the SINAMICS DCM List Manual.
The speed for the JOG function is entered using parameter p50436.
9.3.7.5

Increase setpoint/Decrease setpoint

You can use the Increase and Decrease keys to enter the setpoint with a resolution of 1% of
the maximum speed.
Alternatively, the setpoint can also be entered via the numeric keypad. To do this, press F2
while on the operation screen. The system displays an inverted edit field for entering the
required speed. Enter the required value using the numeric keypad. Press F5 ("OK") to
confirm the setpoint.
Any speed between 0 and the maximum speed (p2000) can be entered using the numeric
keypad.
Setpoint entry in LOCAL mode is unipolar. You can change the direction of rotation by
pressing the key that allows you to switch between CCW/CW rotation.
● CW rotation and "Increase" key mean:
● CCW rotation and "Increase" key mean:
SINAMICS DCM DC Converter
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
in "Operation").
The setpoint displayed is positive and the speed is increased.
The setpoint displayed is negative and the speed is increased.
9.3 Controlling via the AOP30 operator panel
Operation
329