Descriptions of functions
10.2 PROFIBUS
Parameterizing telegram (SetPrm)
The filter table is transferred, as dedicated block from the master to the slave with the
parameterizing telegram when a bus communication is established.
Figure 10-5
Configuration telegram (ChkCfg)
Using the configuration telegram, a slave knows how many setpoints are to be received from
the master and how many actual values are to be sent to the master.
For slave-to-slave communication, a special space ID is required for each tap. The
PROFIBUS configuration tool (e.g. HW Config) generates this ID. The ID is then transferred
with the ChkCfg into the drive devices that operate as subscribers.
10.2.8.4

Commissioning of the PROFIBUS slave-to-slave communication

The commissioning of slave-to-slave communication between two SINAMICS drives using
the additional Drive ES Basic package is described below.
352
Filter block in the parameterizing telegram (SetPrm)
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619
SINAMICS DCM DC Converter