Descriptions of functions
10.33 Drive Control Chart (DCC)
● Step 1
● Step 2
● Step 3
● Step 4
Note
The memory card supplied from Siemens as option S01 or S02 includes, when supplied,
a dump of the internal unit software. These files are only required to update software.
These files can be deleted for all other applications of the memory card. Copy the files
into a local folder of your PG/PC and delete the files on the memory card, before you use
the card for the functions described in this chapter.
502
In STARTER, open a project that includes a SINAMICS DCM drive with at least one DCC
chart. In the shortcut menu (right mouse button), select "Load into file system" (only
possible in the offline mode).
Figure 10-71 Loading into the file system
A dialog, "Load into file system", opens. Choose "Select target" and select an empty
folder on a local hard drive.
After a folder has been selected, STARTER copies the DCB library into this local folder. 2
folders named "OEM" and "USER" are created.
Copy the OEM folder to an empty memory card.
Operating Instructions, 1.2012, C98130-A7066-A1-05-7619