Lenovo System x3850 X6 Installation And Service Manual page 74

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Microprocessor
DIMM 1
DIMM 4
The following illustration shows the DIMM connectors on the non-microprocessor side of the compute book
board.
DIMM 13
DIMM 14
DIMM 15
DIMM 16
DIMM 17
DIMM 18
To install a DIMM, complete the following steps.
1. Before you begin, read "Safety" on page v and "Installation guidelines" on page 44.
2. Turn off the server (see "Turning off the server" on page 40) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
3. Remove the compute book from the server (see "Removing a compute book" on page 291).
4. Remove the compute book cover (left or right cover - depending on the DIMM connector in which you
are installing the DIMM). Press down on both blue touch points on the cover and slide the cover toward
the rear of the expansion module.
Attention: Remove only one cover (on one side) at a time to protect the compute book components on
the other side of the compute book from being damaged.
60
System x3850 X6 and x3950 X6 Installation and Service Guide
DIMM 2
DIMM 3
DIMM 7
DIMM 5
DIMM 6
DIMM 10 DIMM 11 DIMM 12
DIMM 21
DIMM 20
DIMM 19
DIMM 22
DIMM 23
DIMM 24
DIMM 8
DIMM 9