1. AC cycle the machine.
2. Update IMM FW to the latest level.
3. (Trained service technician only) If error persists, replace system board.
Related links
– IBM Flex System and IBM PureFlex Firmware Updates Best Practices
– Removing the standard I/O book
• 806f011b-1f01ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error.
IMM has detected the Storage I/O Book has a cable / interconnect problem.
May also be shown as 806f011b1f01ffff or 0x806f011b1f01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
Storage Book: Card or Drive backplane cable FP LCD Cable: Front Panel LCD cable
1. Remove the Storage Book
2. Check for missing or loose cables in the Storage Book.
3. Check connector for damege or debris.
Related links
– Removing the storage book
• 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName].
The IPMI Watchdog Timer has expired. A reboot of the system was initiated.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
Appendix C. Integrated management module II (IMM2) error messages