1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If this is the only temperature related event and the event persists, replace the system board
(Trained Service personnel only).
Related links
– Server features and specifications
– Removing the standard I/O book
• 80030006-2101ffff : Sensor [SensorElementName] has deasserted.
Secure UEFI (Sig Verify Fail) update completed Successfully.
May also be shown as 800300062101ffff or 0x800300062101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0509
User Response
Information only; no action is required.
• 80030108-1381ffff : Sensor [SensorElementName] has asserted.
Power Supply load has reached normal limit.
May also be shown as 800301081381ffff or 0x800301081381ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0508
User Response
Appendix C. Integrated management module II (IMM2) error messages