CIM Information
Prefix: PLAT ID: 0370
User Response
Information only; no action is required.
• 806f0125-2c05ffff : [ManagedElementName] detected as absent.
IMM has detected that the Storage Book is absent.
May also be shown as 806f01252c05ffff or 0x806f01252c05ffff
Severity
Info
Serviceable
no
Automatically notify support
no
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0392
User Response
1. If the Storage Book was intentionally removed, no action required.
2. Make sure that the Storage Book is properly seated.
3. If Storage Book is properly seated, replace the Storage Book.
Related links
– Removing the storage book board assembly
– Replacing the storage book board assembly
• 806f0207-0301ffff : [ProcessorElementName] has Failed with FRB1/BIST condition.
IMM has reported a Miroprocessor 1 Failed - FRB1/BIST condition.
May also be shown as 806f02070301ffff or 0x806f02070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0044
User Response
844
System x3850 X6 and x3950 X6 Installation and Service Guide