Lenovo System x3850 X6 Installation And Service Manual page 664

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

1. If the Compute Book 1 was intentionally removed, Install Compute Book 1.
2. Make sure that the Compute Book 1 is properly seated.
3. If Compute Book 1 is properly seated, replace the Compute Book 1.
Related links
– Replacing a compute book
– Removing a compute book
• 80070608-1381ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
IMM has detected Power Supply related fault. ( PS 12V OV Fault, PS 12V UV Fault, or PS AUX UV Fault)
May also be shown as 800706081381ffff or 0x800706081381ffff
Severity
Error
Serviceable
yes
Automatically notify support
no
Alert Category
Critical - Power
SNMP Trap ID
4
CIM Information
Prefix: PLAT ID: 0530
User Response
if PS 12V OV Fault or PS 12V UV Fault or PS AUX UV Fault:
1. Check the power supply LEDs, see "Power-supply LEDs".
2. Replace the failing power supply.
Related links
– Solving power problems
– Installing power supplies
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 8007060f-2201ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
Trusted Platform Module (TPM) initialization error.
May also be shown as 8007060f2201ffff or 0x8007060f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
650
System x3850 X6 and x3950 X6 Installation and Service Guide