Lenovo System x3850 X6 Installation And Service Manual page 646

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

– Finding the UEFI (POST) error code
• 80070125-2583ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
A BP2 Pop Error, X8 PCIe1 Config, or X8 PCIe2 Config error has been detected.
May also be shown as 800701252583ffff or 0x800701252583ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
The NVME drive interface card is in the wrong slot. Remove and replace in slot 1.
• 80070201-0301ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
IMM has detected Compute Book 1 has warmed to a critical temperature.
May also be shown as 800702010301ffff or 0x800702010301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80070201-0302ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
632
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents