Information only; no action is required.
• 80010002-2801ffff : Numeric sensor SysBrd VBAT going low (lower non-critical) has asserted.
The CMOS battery voltage has dropped below its specified threshold.
May also be shown as 800100022801ffff or 0x800100022801ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Voltage
SNMP Trap ID
13
CIM Information
Prefix: PLAT ID: 0476
User Response
Replace the CMOS battery.
Related links
– Removing the system battery
• 80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
A Voltage has dropped below its specified threshold (sensor SysBrd 12V, SysBrd 3.3V, or SysBrd 5V).
May also be shown as 800102020701ffff or 0x800102020701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0480
User Response
1. (Trained service technician only) If the specified sensor is SysBrd 3.3V or SysBrd 5V, replace the
system board.
2. If the specified sensor is SysBrd 12V, check the IMM event log for power-supply-related issues,
and resolve those issues. If the problem remains, (trained service technician only) replace the
system board.