Lenovo System x3850 X6 Installation And Service Manual page 773

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
• 806f010d-2b810001 : The [NumericSensorElementName] has been disabled due to a detected fault.
The eXFlash Proxy Service detected a fault on the eXFlash DIMM 1 in Compute Book 1.
May also be shown as 806f010d2b810001 or 0x806f010d2b810001
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0164
User Response
1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
2. Reinstall your eXFlash IPMI Proxy Service.
3. Perform a full AC power cycle on the system.
4. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash
DIMM is properly seated and visually verify that there is no foreign material in any DIMM
connector on that memory channel. If either of these conditions is found, correct and retry with
the same eXFlash DIMM. (Note: Event Log may contain a recent 00580A4 event denoting
detected change in DIMM population that could be related to this problem.)
5. Check IBM support site for an applicable service bulletin or firmware update that applies to this
eXFlash error.
6. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that
the eXFlash DIMM is under warranty before replacement.
7. Replace compute book.
8. (Trained Service technician only) Replace affected Processor.
Appendix C. Integrated management module II (IMM2) error messages
759

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents