Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 800b010a-1e83ffff : Redundancy Lost for [RedundancySetElementName] has asserted.
Fan Redundancy in Zone 3 has been lost.
May also be shown as 800b010a1e83ffff or 0x800b010a1e83ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 800b010a-1e84ffff : Redundancy Lost for [RedundancySetElementName] has asserted.
Fan Redundancy in Zone 4 has been lost.
May also be shown as 800b010a1e84ffff or 0x800b010a1e84ffff
Severity
Error
Serviceable
660