Lenovo System x3850 X6 Installation And Service Manual page 210

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Customer
label space
Machine type and
model number
• Machine type and model
• Microprocessor or hard disk drive upgrades
• Failure symptom
– Does the server fail the Dynamic System Analysis diagnostic tests?
– What occurs? When? Where?
– Does the failure occur on a single server or on multiple servers?
– Is the failure repeatable?
– Has this configuration ever worked?
– What changes, if any, were made before the configuration failed?
– Is this the original reported failure?
• Diagnostic program type and version level
• Hardware configuration (print screen of the system summary)
• UEFI firmware level
• IMM firmware level
• Operating-system software
You can solve some problems by comparing the configuration and software setups between working and
nonworking servers. When you compare servers to each other for diagnostic purposes, consider them
identical only if all the following factors are exactly the same in all the servers:
• Machine type and model
• UEFI firmware level
• IMM firmware level
• Adapters and attachments, in the same locations
• Address jumpers, terminators, and cabling
• Software versions and levels
• Diagnostic program type and version level
196
System x3850 X6 and x3950 X6 Installation and Service Guide
Customer
label space

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents