Lenovo System x3850 X6 Installation And Service Manual page 696

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0850
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 806f000f-22010cff : CPU voltage mismatch detected on [ProcessorElementName].
IMM has reported a microprocessor voltage mismatch (ABR Status, Firmware Error, Sys Boot Status, X8
PCIe1 Firm, X8 PCIe2 Firm) with the microprocessor socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - CPU
SNMP Trap ID
40
CIM Information
Prefix: PLAT ID: 0050
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 806f000f-2201ffff : The System [ComputerSystemElementName] encountered a POST Error.
IMM has reported a Post Error (ABR Status, Firmware Error, Sys Boot Status, X8 PCIe1 Firm, X8 PCIe2
Firm).
May also be shown as 806f000f2201ffff or 0x806f000f2201ffff
Severity
Error
Serviceable
682
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents