Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
Related links
– Solving power problems
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 800b0309-1381ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
Power Resource is supplying sufficient power but is no longer in a redundancy state.
May also be shown as 800b03091381ffff or 0x800b03091381ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0806
User Response
1. Power Unit: Check if Power Supply is missing, unplugged.
2. Check the log and resolve power supply issues.
Related links
– Solving power problems
• 800b030c-2581ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for Backup Memory has asserted.
Backup Memory has transitioned from Redundancy Degraded or Fully Redundant to Non-redundant:
Sufficient.
May also be shown as 800b030c2581ffff or 0x800b030c2581ffff
Appendix C. Integrated management module II (IMM2) error messages
663