• 80070107-2583ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
How the CPU's are installed in the system does not match a supported configuration and may make
CPU's inaccessible to the operating system and prevent boot. [CPU Population]
May also be shown as 800701072583ffff or 0x800701072583ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following steps:
1. Check the IBM ServerProven Web site to validate that the processor is a valid option for this
system. If not, remove the processor and install one that is a valid option.
2. Verify that matching processors are installed in the correct population sequence for the system.
See the system documentation.
3. Check the IBM support site for service bulletins or firmware updates that apply to this processor
error.
4. Replace the processor. While replacing the processor, inspect the processor socket and replace
the CPU / Memory board if the processor socket is damaged.
Related links
– Replacing a compute book
Appendix C. Integrated management module II (IMM2) error messages
581