Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 80010701-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted.
IMM has detected that the ambient temperature has risen above normal.
May also be shown as 800107012701ffff or 0x800107012701ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80010701-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical)
has asserted.
The PCH temperature has risen above normal.
May also be shown as 800107012d01ffff or 0x800107012d01ffff