2. If the specified sensor is Planar 12V, check the IMM Web event log for power-supply-related
issues, and resolve those issues.: If the problem remains, (trained service technician only) replace
the system board.
Related links
– Removing the standard I/O book
• 80010b01-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted.
The ambient temperature has risen above its threshold. A hard shutdown has occurred.
May also be shown as 80010b012701ffff or 0x80010b012701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80010b01-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper non-
recoverable) has asserted.
The PCH temperature sensor has risen above its threshold. A hard shutdown has occurred.
May also be shown as 80010b012d01ffff or 0x80010b012d01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0498