Lenovo System x3850 X6 Installation And Service Manual page 861

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 806f020d-0400ffff : Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
Failure predicted (PFA) on the hard drive 0.
May also be shown as 806f020d0400ffff or 0x806f020d0400ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Replace the hard disk drive at the next maintenance period.
Related links
– Removing 2.5-inch and 1.8-inch hot-swap drives
– Replacing 2.5-inch and 1.8-inch hot-swap drives
• 806f020d-0401ffff : Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
Failure predicted (PFA) on the hard drive 1.
May also be shown as 806f020d0401ffff or 0x806f020d0401ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
Yes
Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
Replace the hard disk drive at the next maintenance period.
Appendix C. Integrated management module II (IMM2) error messages
847

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents