Lenovo System x3850 X6 Installation And Service Manual page 570

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

– Removing the standard I/O book
• 80010202-2801ffff : Numeric sensor SysBrd VBAT going low (lower critical) has asserted.
The CMOS battery voltage has dropped below its specified threshold.
May also be shown as 800102022801ffff or 0x800102022801ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Voltage
SNMP Trap ID
1
CIM Information
Prefix: PLAT ID: 0480
User Response
Replace the CMOS battery.
Related links
– Removing the system battery
• 80010204-1d01ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
IMM has detected the speed of Fan 1A or Fan 1B has gone low.
May also be shown as 800102041d01ffff or 0x800102041d01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 80010204-1d02ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
556
System x3850 X6 and x3950 X6 Installation and Service Guide