Information only; no action is required.
• 806f000d-040effff : The [NumericSensorElementName] has been added.
Hard drive 14 has been installed.
May also be shown as 806f000d040effff or 0x806f000d040effff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
Information only; no action is required.
• 806f000d-040fffff : The [NumericSensorElementName] has been added.
Hard drive 15 has been installed.
May also be shown as 806f000d040fffff or 0x806f000d040fffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Hard Disk drive
SNMP Trap ID
5
CIM Information
Prefix: PLAT ID: 0162
User Response
Information only; no action is required.
• 806f000f-220101ff : The System [ComputerSystemElementName] has detected no memory in the
system.
IMM has reported that there is no memory (ABR Status, Firmware Error, Sys Boot Status, X8 PCIe1 Firm,
X8 PCIe2 Firm ) in the system.
May also be shown as 806f000f220101ff or 0x806f000f220101ff
Severity
Error
Serviceable