Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524
User Response
Complete the following steps until the problem is solved:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the microprocessor 3 heat sink is securely installed.
5. (Trained service technician only) Make sure that the microprocessor 3 heat sink is installed
correctly and the thermal material is correctly applied.
6. (Trained service technician only) Replace microprocessor 3.
Related links
– Server features and specifications
– Removing a microprocessor and heat sink
– Replacing a microprocessor and heat sink
– Thermal grease
• 80070301-0304ffff : Sensor [SensorElementName] has transitioned to non-recoverable from a less
severe state.
IMM has detected that the temperature for microprocessor 4 has transitioned to a non recoverable state.
May also be shown as 800703010304ffff or 0x800703010304ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0524
User Response
Appendix C. Integrated management module II (IMM2) error messages
645