Step 6.
Reconnect the front operator panel cable to the storage book board.
Step 7.
Reinstall the storage book in the server.
Step 8.
Reconnect the power cords and any cables that you removed.
Step 9.
Turn on the peripheral devices and the server.
Step 10. Update the LCD system information display panel part number, FRU part number, serial number,
and prefix serial number in the customer records, service offering support information, and
component Vital Product Data (VPD) using the Advanced Settings Utility (ASU) program. For more
information about using ASU and additional command options, see "Advanced Settings Utility
program" on page 140.
a.
Update component part number in customer records and service offering support
information
The component part number is the first seven characters following the "11S" of the 11S
barcode. In the following example, the component part number is shown in bold:
11S12X4567YJ1105A34567
b.
Update component part number VPD
Use the following ASU command to update the component VPD:
asu64 set VPD.CompVPD_PartNumber.4 "<p/n>[sp][sp][sp][sp][sp]"
where:
<p/n> is the 7–character component part number followed by five padding spaces.
c.
Update component serial number and prefix serial number in customer records and
service offering support information
The serial number is the last six characters of the 11S barcode. In the following example, the
serial number is shown in bold:
11S12X4567YJ1105A34567
The prefix serial number is the six characters of the 11S barcode that follow the first 10
characters of the 11S barcode (the six characters preceding the component serial number
.