Lenovo System x3850 X6 Installation And Service Manual page 571

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

IMM has detected the speed of Fan 2A or Fan 2B has gone low.
May also be shown as 800102041d02ffff or 0x800102041d02ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 80010204-1d03ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
IMM has detected the speed of Fan 3A or Fan 3B has gone low.
May also be shown as 800102041d03ffff or 0x800102041d03ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0480
User Response
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related links
– Removing a hot-swap fan assembly
• 80010204-1d04ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted.
IMM has detected the speed of Fan 4A or Fan 4B has gone low.
Appendix C. Integrated management module II (IMM2) error messages
557

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents