CIM Information
Prefix: IMM ID: 0059
User Response
Complete the following steps until the problem is solved:
1. Make sure that the IMM network cable is connected.
2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to the
IMM.
• 4000003c-00000000 : Platform Watchdog Timer expired for [arg1].
IMM has detected an OS did not start in the expected amount of time.
May also be shown as 4000003c00000000 or 0x4000003c00000000
Severity
Error
Serviceable
No
Automatically notify support
No
Alert Category
System - Loader timeout
SNMP Trap ID
26
CIM Information
Prefix: IMM ID: 0060
User Response
1. Reconfigure the watchdog timer to a higher value.
2. Make sure that the IMM Ethernet over USB interface is enabled.
3. Reinstall the RNDIS or cdc_ether device driver for the operating system.
4. Disable the watchdog.
5. Check the integrity of the installed operating system
• 4000003d-00000000 : Telnet port number changed from [arg1] to [arg2] by user [arg3].
The specified user has changed the Telnet port number.
May also be shown as 4000003d00000000 or 0x4000003d00000000
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
none
SNMP Trap ID
CIM Information
Prefix: IMM ID: 0061
Appendix C. Integrated management module II (IMM2) error messages
501