Lenovo System x3850 X6 Installation And Service Manual page 588

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the Compute Book are not obstructed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80070101-0303ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
A non-critical Overtemp has been reported for the Compute Book 3.
May also be shown as 800701010303ffff or 0x800701010303ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0520
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the Compute Book are not obstructed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80070101-0304ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
A non-critical Overtemp has been reported for the Compute Book 4.
May also be shown as 800701010304ffff or 0x800701010304ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
574
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents