Lenovo System x3850 X6 Installation And Service Manual page 576

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Temperature
SNMP Trap ID
12
CIM Information
Prefix: PLAT ID: 0490
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80010901-2701ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
IMM has detected that the ambient temperature has risen above its upper critical threshold.
May also be shown as 800109012701ffff or 0x800109012701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0494
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80010901-2d01ffff : Numeric sensor [NumericSensorElementName] going high (upper critical) has
asserted.
562
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents