Use the following ASU command to update the FRU part number VPD:
asu64 set VPD.CompVPD_FRUNumber.# "<fru_number>[sp][sp][sp][sp][sp]"
where:
• # is 1 for a 4-socket midplane and 2 for an 8-socket midplane.
• <fru_number> is the 7–character FRU part number above followed by five padding spaces.
Step 10. Restart the IMM2; then, restart the server.
Removing the shuttle
Use this information for instructions on how to remove the chassis shuttle.
To remove the chassis shuttle, complete the following steps:
Step 1.
Before you begin, read "Safety" on page v and "Installation guidelines" on page 44 .
Step 2.
Turn off the server (see "Turning off the server" on page 40) and all attached peripheral devices.
Disconnect all power cords; then, disconnect all external cables from the server.
Step 3.
Slide all of the components in the front of the server out slightly
Step 4.
Remove all of the components from the rear of the server.
Step 5.
Remove the shuttle.
• For the 4U server configuration, do the following:
1. Press the blue buttons on the interior wall of the shuttle to release the shuttle cam handles
and rotate the handles all the way down.
2. Grasp the shuttle with your hand through the hole on the center of the shuttle and grasp the
bottom of the shuttle with your other hand and slide the shuttle out of the chassis.
• For the 8U server configuration, do the following:
1. Press the blue buttons on the interior wall of the bottom node shuttle to release the shuttle
cam handles (do not rotate the handles down).