SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 80070625-2583ffff : Sensor [SensorElementName] has transitioned to non-recoverable.
A X8 PCIe1 Config or X8 PCIe2 Config mismatch has been detected.
May also be shown as 800706252583ffff or 0x800706252583ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
Firmware of the PCI redrive card and NVME drive interface do not match. Update the firmware.
• 80070808-1381ffff : Sensor [SensorElementName] has an informational state.
Power policies for each node do not match.
May also be shown as 800708081381ffff or 0x800708081381ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
164
CIM Information
Prefix: PLAT ID: 0534
User Response
Appendix C. Integrated management module II (IMM2) error messages