Lenovo System x3850 X6 Installation And Service Manual page 676

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0802
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
– Finding the UEFI (POST) error code
• 800b0208-1381ffff : Redundancy Degraded for [RedundancySetElementName] has asserted.
Power unit is no longer in the redundant state.
May also be shown as 800b02081381ffff or 0x800b02081381ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Redundant Power Supply
SNMP Trap ID
10
CIM Information
Prefix: PLAT ID: 0804
User Response
1. Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
Related links
– Solving power problems
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 800b0308-1381ffff : Non-redundant:Sufficient Resources from Redundancy Degraded or Fully
Redundant for [RedundancySetElementName] has asserted.
Power Supply is supplying sufficient power but is no longer in a redundancy state.
May also be shown as 800b03081381ffff or 0x800b03081381ffff
Severity
Warning
Serviceable
Yes
662
System x3850 X6 and x3950 X6 Installation and Service Guide

Advertisement