– Removing a compute book
• 80070108-1381ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
The IMM has detected a Power Supply configuration error or PS 12V OC Fault or PS CSF Fault.
May also be shown as 800701081381ffff or 0x800701081381ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Power
SNMP Trap ID
164
CIM Information
Prefix: PLAT ID: 0520
User Response
if PS 12V OC Fault is reported
Clear the over current condition.
if PS CSF Fault Fault is reported
Check if there is any other Power Supply event.
if PS ac input src
1. Check if there is any other Power Supply event.
2. confirm power policy and configuration setting in Web GUI.
3. check line feeds.
4. check documentation for correct configuration.
Related links
– Solving power problems
– Installing power supplies
• 8007010d-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
This message is for the use case when an implementation has detected a Sensor transitioned to non-
critical from normal.
May also be shown as 8007010d2582ffff or 0x8007010d2582ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
582