IMM has detected Compute Book 2 has warmed to a critical temperature.
May also be shown as 800702010302ffff or 0x800702010302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
– Server features and specifications
• 80070201-0303ffff : Sensor [SensorElementName] has transitioned to critical from a less severe
state.
IMM has detected Compute Book 3 has warmed to a critical temperature.
May also be shown as 800702010303ffff or 0x800702010303ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0522
User Response
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
Related links
Appendix C. Integrated management module II (IMM2) error messages
633