• 800b0509-1381ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
Power Resource (Power Supply) is no longer in the redundant state and no longer capable of providing the
power needs to operate the system.
May also be shown as 800b05091381ffff or 0x800b05091381ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Check if Power Supply is missing, unplugged.
2. Check the power configuration and power policy.
3. Replace the affected power supply.
Related links
– Solving power problems
– Installing power supplies
– Removing a 1400-watt or 900-watt hot-swap power supply
– Removing a 750-watt -48 volt to -60 volt dc power supply
– Replacing a 1400-watt or 900-watt hot-swap power supply
– Replacing a 750-watt -48 volt to -60 volt dc power supply
• 800b050a-1e81ffff : Non-redundant:Insufficient Resources for [RedundancySetElementName] has
asserted.
Insufficient cooling provided by Fan Zone 1.
May also be shown as 800b050a1e81ffff or 0x800b050a1e81ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
Appendix C. Integrated management module II (IMM2) error messages
665

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x66241

Table of Contents