Fan Speed Switch (Model 31903 And 31909) - Toro Groundmaster Series Service Manual

Table of Contents

Advertisement

Fan Speed Switch (Model 31903 and 31909)

Testing the Fan Speed Switch
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
POSITION
CLOSED
CIRCUITS
OFF
NONE
LOW
B + C + L
MED
B + C + M
HIGH
B + C + H
The fan speed switch is located in the cab headliner. The switch is used to select
the fan speed (off, low, medium, or high). The fan speed switch receives power
from fuse F−2 (40 Amp) in the cab fuse block.
1. Park the machine on a level surface, lower the cutting unit (or attachment),
engage the parking brake, set the key switch to the O
the key from the key switch.
2. Disconnect the battery negative (-) cable at the battery; refer to
and Installing the Battery (page
3. Remove the roof from the cab.
4. Disconnect the wire harness connector from the switch and remove the
switch from the control panel if necessary. Check the switch and the harness
connector for damage or corrosion and clean or repair if necessary.
5. Use a multimeter (ohms setting) and the preceding table to determine
whether continuity exists between the various terminals for each switch
position.
6. Replace the switch if necessary.
7. If the switch tests correctly and a circuit problem still exists, check the wire
harnesses; refer to
8. Install the switch, connect the wire harness, inspect and repair the roof seals
if necessary, and install the roof after testing.
9. Connect the battery negative (-) cable at the battery.
6–64).
Appendix A (page
A–1).
Page 6–39
Electrical System: Testing the Electrical Components
position and remove
FF
Removing

Hide quick links: