Servicing The Battery - Toro Groundmaster Series Service Manual

Table of Contents

Advertisement

Servicing the Battery

Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
g307125
1.
Battery
2.
Battery cover
3.
Battery clamp
4.
Negative (-) cable
5.
Boot
6.
Positive (+) cable
Battery Specifications
Battery-electrolyte specific gravity
Battery specifications
Battery dimensions (including terminal posts
and caps)
The battery is the heart of the electrical system. With the regular and correct
service, the battery life can be extended. Additionally, the battery and electrical
component failure can be prevented.
Figure 107
7.
Starter connection
8.
Alternator cable
9.
Fusible link harness
10.
Engine ground connection
11.
Cap screw
12.
Chassis ground connection
Fully Charged: 1.25 to 1.28 at 27°C (80°F)
Discharged: less than 1.24
BCI Group 26
540 CCA at -18°C (0°F)
Reserve Capacity of 80 minutes at 27°C (80°F)
Length 22.4 cm (8.8 inches)
Width 13.2 cm (6.6 inches)
Height 18.3 cm (8.0 inches)
Page 6–63
Electrical System: Service and Repairs

Hide quick links:

Advertisement

Table of Contents
loading