Toro Groundmaster Series Service Manual page 35

Table of Contents

Advertisement

Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
Multimeter
Obtain this tool locally
The meter can test the electrical
components and circuits for current,
resistance, or voltage.
Note: Use a digital multimeter when
testing the electrical circuits. The high
impedance (internal resistance) of a digital
meter in the voltage mode ensures that
the excess current is not allowed through
the meter. This excess current can
damage the circuits that are not designed
to carry it.
Battery Terminal Protector
Toro Part No. 107-0392
Use this aerosol spray on the battery
terminals, ring terminals, and fork terminals
to reduce corrosion problems. Apply the
terminal protector to the connection after
you secure the battery cable, ring terminal,
or fork terminal.
Dielectric Gel
Toro Part No. 107-0342
Use the dielectric gel to prevent
corrosion of unsealed connection
terminals. To ensure that the
terminals are completely coated,
liberally apply the gel to the
component and wire harness
connector, plug the connector
into the component, unplug the
connector, apply the gel to both
surfaces again, and connect
the harness connector to the
component again. The connectors
must be fully packed with gel for
effective results.
Note: Do not use the dielectric gel
on the sealed connection terminals
as the gel can unseat the connector
seals during assembly.