Toro Groundmaster Series Service Manual page 207

Table of Contents

Advertisement

Fuse Identification and Function (continued)
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
Fuse F-1 (open slot) supplies switched power available for optional
equipment.
Fuse F-2 (40 Amp) supplies switched power to the mixing box blower, the
defroster blower and the dome light.
Fuse F-3 (20 Amp) supplies switched power to the windshield wipers and
washer pump.
Fuse F-4 (25 Amp) supplies switched power to the condenser fans and
compressor clutch.
Road Light Kit (Optional) – Fuse Block
g306148
1.
Control pod fuse block
2.
Access panel
Fuse F-1 (10 Amp) supplies switched power to the work lights.
Fuse F-2 (10 Amp) supplies switched power to the beacon.
Fuse F-3 (10 Amp) supplies switched power to the road lights.
Fuse F-4 (15 Amp) supplies switched power to the horn.
Road Light Kit (Optional) – Harness
Figure 82
3.
Knob (2 each)
Page 6–15
Electrical System: Testing the Electrical Components