Toro Groundmaster Series Service Manual page 43

Table of Contents

Advertisement

Machine Faults (continued)
Machine Faults (continued)
Fault
Fault Title
ID
C1414
Solenoid Valve 1
(SV1) - Short to
Ground/Overcurrent
C1415
Solenoid Valve 1 (SV1)
- Open Circuit
C1423
Solenoid Valve 2 (SV2)
- Short to Battery
C1424
Solenoid Valve 2
(SV2) - Short to
Ground/Overcurrent
C1425
Solenoid Valve 2 (SV2)
- Open Circuit
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
Fault
Condition/Circuit
Additional Notes
Description
Overcurrent
detected in SV1
output circuit,
indicating a short
to ground.
Open circuit
detected on SV1
output circuit.
Low current
The short could be
detected on
to battery voltage
the SV2 output
or to another signal
circuit. Indicates
that is in a high (+)
a short to a high
state.
(+) source.
Overcurrent
detected in SV2
output circuit,
indicating a short
to ground.
Open circuit
detected on SV2
output circuit.
Page 3–7
Service Actions
1.
Check the wire harness connectors
(P100, P31) for damage or corrosion and
clean or repair if necessary.
2.
Test the SV1 output circuit wiring.
3.
Test the SV1 valve solenoid and cartridge
valve.
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Check the wire harness connectors
(P100, P31) for damage or corrosion and
clean or repair if necessary.
2.
Test the SV1 output circuit wiring.
3.
Test the SV1 valve solenoid and cartridge
valve.
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Check the wire harness connectors
(P100, P32) for damage or corrosion and
clean or repair if necessary.
2.
Test the SV2 output circuit wiring.
3.
Test the SV2 valve solenoid and cartridge
valve.
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Check the wire harness connectors
(P100, P32) for damage or corrosion and
clean or repair if necessary.
2.
Test the SV2 output circuit wiring.
3.
Test the SV2 valve solenoid and cartridge
valve.
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
1.
Check the wire harness connectors
(P100, P32) for damage or corrosion and
clean or repair if necessary.
2.
Test the SV2 output circuit wiring.
3.
Test the SV2 valve solenoid and cartridge
valve.
4.
Swap the TDM controller with a
known-good unit (contact an Authorized
Toro Distributor for assistance).
Troubleshooting: Cutting Unit (or attachment) Problems