Machine Faults (continued)
Machine Faults (continued)
Fault
Fault Title
ID
P06E9
Starter Timeout
P100C
Engine Coolant
Temperature Above
Threshold - PTO
Disabled
P100D
Engine Coolant
Temperature Above
Threshold - Engine
Shut Down
P2530
Key Start/Run
Correlation Fault
Groundsmaster
®
3200, 3300 and 3310
19240SL Rev A
Fault
Condition/Circuit
Additional Notes
Description
Starter has
Starter is disabled.
been engaged
continuously for
more than 30
seconds.
Engine coolant
PTO is disabled.
temperature has
exceeded 105° C
(221° F)
Engine coolant
Engine is shut down.
temperature has
exceeded 115° C
(239° F)
Key start input
Machine will shut
is active but the
down since key run
key run input is
input is inactive.
inactive.
Page 3–9
Service Actions
1.
Verify the key switch is not stuck in the
start position.
2.
Check the wire harness connector (P26)
for damage or corrosion and clean or
repair if necessary.
3.
Test key switch and replace if necessary.
1.
Allow the engine to cool.
2.
Check the fan condition and operation.
3.
Clear the air flow screens and passages.
4.
Check the coolant level and condition,
adjust and replace the coolant if
necessary.
5.
Check the temperature sender wiring and
connector.
• Model 31900/01 (P100, J05)
• Model 31902/03 (P01, P240, Yanmar
engine wire harness at the temperature
sender).
6.
Test temperature sender and replace if
necessary.
1.
Allow the engine to cool.
2.
Check the fan condition and operation.
3.
Clear the air flow screens and passages.
4.
Check the coolant level and condition,
adjust and replace the coolant if
necessary.
5.
Check the temperature sender wiring and
connector.
• Model 31900/01 (J05)
• Model 31902/03 (P01, P240, Yanmar
engine wire harness at the temperature
sender).
6.
Test temperature sender and replace if
necessary.
1.
Test fuse F3 in fuse block 1 (10A) and
replace if necessary.
2.
Check the wire harness connector (P26,
P100) for damage or corrosion and clean
or repair if necessary.
3.
Test the circuit wiring between fuse
F3 in fuse block 1 (10A) and the TDM
controller.
4.
Test the key switch and replace if
necessary.
Troubleshooting: Cutting Unit (or attachment) Problems