Huawei Tecal RH5485 Problem Determination And Service Manual page 99

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

Tecal RH5485 Server
Problem Determination and Service Guide
Message
Non-redundant: Insufficient
resources for Cooling Zone
2 has asserted.
Non-redundant: Insufficient
resources for Cooling Zone
3 has asserted.
The Drive n Status has
been removed from unit
chassis 1.
(n = hard disk drive number)
The Drive n Status has
been dis- abled due to a
detected fault.
(n = hard disk drive number)
Issue 02 (2011-05-25)
Severity Description
Warning Redundancy is insufficient and
might degrade or interrupt system
operation.
Warning Redundancy is insufficient and
might degrade or interrupt system
operation.
Error
A drive has been removed.
Error
A drive has been disabled
because of a fault.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Diagnostics
Action
1. Make sure that the
connectors on fans 2 and 3 are
not damaged.
2. Make sure that fan
connectors 2 and 3 on the
microprocessor board are not
damaged.
3. Make sure that the fans are
correctly installed.
4. Reseat the fans.
5. Replace the fans.
1.
Make sure that the
connector on fan 3 is not
damaged.
2.
Make sure that fan
connector
3 on the microprocessor board is
not damaged.
3.
Make sure that the fan is
correctly installed.
4.
Reseat the fan.
5. Replace the fans.
Reseat hard disk drive n.
(n = hard disk drive number)
1. Run the hard disk drive
diagnostic test on drive n.
2. Reseat the following
components:
a. Hard disk drive b. Cable
from the
microprocessor board to
the backplane
3. Replace the following
components one at a time, in the
order shown, restarting the server
each time:
a. Hard disk drive b. Cable
from the
microprocessor board to
the backplane
c. Hard disk drive backplane
(n = hard disk drive number)
3-81

Advertisement

Table of Contents
loading

Table of Contents