3 Diagnostics
0011004
001100A
3-24
Invalid microprocessor type
Microprocessor mismatch
Microprocessor
built-in self-test (BIST)
Microcode update failed
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Problem Determination and Service Guide
microprocessor 2 in the microprocessor 1
connector. Restart the server. If the error is
corrected, microprocessor 1 is bad and
must be replaced. Repeat this step for
microprocessors 2, 3, and 4 if necessary.
4.
Replace the following components one at
a time, in the order shown, restarting the
server each time:
a)
(Trained service technician only)
Microprocessor 1
b)
(Trained service technician only)
Microprocessors 2, 3, and 4
c)
(Trained service technician only)
Microprocessor board
Update the firmware (see "Updating the
1.
firmware").
2.
(Trained service technician only) Remove
and replace the affected microprocessor
(error LED is lit) with a supported type.
1.
Run the Setup utility and view the
microprocessor information to compare
the
specifications.
2.
(Trained service technician only) Remove
and replace one of the microprocessors so
that they both match.
1. Update the firmware (see "Updating the
failed
firmware").
2. (Trained service technician only) Reseat
microprocessor 2.
3. Replace the following components one at a
time, in the order shown, restarting the server
each time:
a.
(Trained
Microprocessor
b.
(Trained
Microprocessor board
1. Update the server firmware (see "Updating
the
firmware" ).
2. (Trained service technician only) Replace
the
microprocessor.
Tecal RH5485 Server
installed
microprocessor
service
technician
service
technician
Issue 02 (2011-05-25)
only)
only)