3 Diagnostics
3818001
3818002
3818003
3818004
3818005
3818006
3818007
3828004
3-30
Core
Root
of
Measurement
update failed
Core
Root
of
Measurement
(CRTM)update aborted
Core
Root
of
Measurement (CRTM)flash
lock failed
Core
Root
of
Measurement
(CRTM)system error
Current Bank Core Root of
Trust Measurement (CRTM)
capsule signature invalid
Opposite
bank
capsule signature invalid
CRTM
update
signature invalid
AEM
power
disabled
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Problem Determination and Service Guide
from the operating system.
When using the local console:
1. Run the Setup utility.
2. Select System Event Logs.
3. Select Clear System Event Log.
4. Restart the server.
Trust
1. Run the Setup utility, select Load Default
(CRTM)
Settings, and save the settings.
2. (Trained service technician only) Replace
the
microprocessor board.
Trust
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace
the microprocessor board.
Trust
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace
the microprocessor board.
Trust
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace
the microprocessor board.
1. Run the Setup utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace
the microprocessor board.
CRTM
1. Switch the firmware bank to the backup
bank.
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Switch the bank back to the current bank.
4. (Trained service technician only) Replace
the microprocessor board.
1. Run the Setup utility, select Load Default
capsule
Settings, and save the settings.
2. (Trained service technician only) Replace
the microprocessor board.
capping
1. Check the settings and the event logs.
2. Make sure that the Active Energy Manager
feature is enabled in the Setup utility. Select
System Settings > Power > Active
Tecal RH5485 Server