System-Event Log; Integrated Management Module Error Messages; Table 3-20 Integrated Management Module (Imm) Error Messages (Server) - Huawei Tecal RH5485 Problem Determination And Service Manual

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

Tecal RH5485 Server
Problem Determination and Service Guide

3.10 System-event log

The system-event log contains messages of three types:

3.11 Integrated management module error messages

The following tables list messages that might be displayed in the integrated management
module (IMM) event log. You can view the IMM event log through the IMM Web interface.

Table 3-20 Integrated management module (IMM) error messages (server)

Message
Temperature and fan messages
Numeric sensor Ambient
Temp going high (upper
non-critical) has asserted.
Numeric sensor Ambient
Temp going high (upper
critical) has asserted.
Numeric sensor Ambient
Temp going high
non-recoverable)
has asserted.
Numeric sensor Ambient
Temp going high (upper
critical) has deasserted.
Issue 02 (2011-05-25)
Information
Information messages do not require action; they record significant system-level events,
such as when the server is started.
Warning
Warning messages do not require immediate action; they indicate possible problems,
such as when the recommended maximum ambient temperature is exceeded.
Error
Error messages might require action; they indicate system errors, such as when a fan is
not detected.
Each message contains date and time information, and it indicates the source of the
message (POST or the IMM).
Follow the suggested actions in the order in which they are listed in the Action column
until the problem is solved.
See Chapter 4, "Parts listing, RH 5485," to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
If an action step is preceded by "(Trained service technician only)," that step must be
performed only by a trained service technician.
Severity Description
Warning An upper non-critical sensor
Error
Error
(upper
Info
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
going high has asserted.。
An upper critical sensor going
high has asserted.
An upper nonrecoverable sensor
going high has asserted.
An upper non-critical sensor
going high has deasserted.
3 Diagnostics
Action
No action, warning of increased
temperature
Reduce the ambient temperature.
Reduce the ambient temperature.
No action; information only.
3-65

Advertisement

Table of Contents
loading

Table of Contents