Tecal RH5485 Server
Problem Determination and Service Guide
Step 1 Read the safety information and "Installation guidelines".
Step 2 If only one power supply is installed, turn off the server.
Step 3 Disconnect the power cord from the connector on the back of the power supply.
Step 4 Slide the orange release latch on the handle to the right and lift the handle up to the open
position.
Step 5 Pull the power supply out of the bay.
Step 6 If you are instructed to return the hot-swap power supply, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.
----End
Replacing the hot-swap power supply
To install the replacement hot-swap power supply, complete the following steps:
Step 1 Touch the static-protective package that contains the power supply to any unpainted surface
on the outside of the server; then, remove it from the package.
Step 2 Press the orange release latch on the handle to the right and pull the handle up to the open
position if it is not already in the open position.
Step 3 Push the power supply into the bay, slide the latch to the right, and push the handle down to
lock it.
Step 4 Connect one end of the power cord for the new power supply into the ac inlet on the back of
the power supply, and connect the other end of the power cord into a properly grounded
electrical outlet.
Step 5 Route the cable through the retention hook on the back of the power supply.
Issue 02 (2011-05-25)
NOTE
If your server has only one power supply, you must turn off the server before you remove the power
supply.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.