Huawei Tecal RH5485 Problem Determination And Service Manual page 92

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

3 Diagnostics
Message
A
Uncorrectable
Error
has
occurred on
system %1.
(%1 = CIM_ComputerSystem
.ElementName)
A
Uncorrectable
Error
has
occurred on
system %1.
(%1 = CIM_ComputerSystem
.ElementName)
3-74
Severity Description
Bus
Error
A bus uncorrectable error has
occurred.
(Sensor = Critical Int CPU)
Bus
Error
A bus uncorrectable error has
occurred.
(Sensor = Critical Int DIMM)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Tecal RH5485 Server
Problem Determination and Service Guide
Action
1. Check the system-event log.
2. Check the microprocessor
error LEDs.
3. Remove the failing
microprocessor from the
microprocessor board.
4. Check for a server firmware
update.
Important:
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
5. Make sure that all of the
installed microprocessors are
matching.
6. (Trained service technician
only) Replace the microprocessor
board.
1. Check the system-event log.
2. Check the DIMM error
LEDs.
3. Remove the failing DIMM
from the memory board.
4. Check for a server firmware
update.
Important:
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
5. Make sure that the installed
DIMMs are supported and
configured correctly.
6. (Trained service technician
only) Replace the failing memory
card.
Issue 02 (2011-05-25)