Tecal RH5485 Server
Problem Determination and Service Guide
Message
Fault in slot PCI n on
system SN# ZZZZZZP.
Non-redundant: Insufficient
resources for Backup Memory
has asserted.
Non-redundant: Sufficient
resources form Redundancy
Degraded or Fully Redundant
for Backup Memory has
asserted.
Sensor Mem Lane Spared
has asserted
Sensor Planar Fault has
transitioned to critical from
a less severe state.
Issue 02 (2011-05-25)
Severity Description
Error
A fault has occurred in PCI slot
n.
Error
Redundancy Lost for Backup
Memory has asserted.
Error
Redundancy Lost for Backup
Memory has asserted.
Info
A recoverable error has occurred
on a memory card interface.
Error
A sensor has changed to Critical
state from a less severe state.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 Diagnostics
Action
1.
Check the riser-card LEDs.
2.
Reseat the affected
adapters.
3.
Update the server and
adapter firmware (UEFI and
IMM).
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster solution
before you update
the code.
4.
Remove the adapter from
slot n.
5.
Replace the PCI Express
adapter.
1.
Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2.
Re-enable mirroring in the
Setup utility.
1.
Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
2.
Re-enable mirroring in the
Setup utility.
1.
Check the system-event log
for memory card failure
events (uncorrectable or PFA)
and correct the failures.
2.
Reseat the memory card.
3.
Replace the failing memory
card.
(Trained service technician only)
Replace the microprocessor
board.