Huawei Tecal RH5485 Problem Determination And Service Manual page 94

Hide thumbs Also See for Tecal RH5485:
Table of Contents

Advertisement

3 Diagnostics
Message
Sensor VT Fault has
transitioned to non-recoverable.
Sensor VT Fault has
transitioned from normal to
non-critical state.
Sensor
P wr
Rail
Fault
has
transitioned to
non-recoverable.
Sensor
Pwr
Rail
Fault
has
transitioned to
non-recoverable.
3-76
Severity Description
Error
A sensor has changed to
Nonrecoverable state
Warning
A sensor has transitioned to a
non-critical state.
A
Error
A sensor has changed to
Nonrecoverable state.
B
Error
A sensor has changed to
Nonrecoverable state.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Tecal RH5485 Server
Problem Determination and Service Guide
Action
1.
Check the power-supply
LEDs.
2.
Follow the actions in
"Power-supply LEDs".
3.
Replace the failing power
supply.
4.
(Trained service technician
only) Replace the I/O-board
shuttle.
No action; information only.
1.
Turn off the server and
disconnect it from power.
2.
(Trained service technician
only) Remove the
microprocessor from socket 1.
Note: The server will not
start when no microprocessor is
installed in socket 1.
3.
Reinstall the
microprocessor in socket 1 and
restart the server.
4.
(Trained service technician
only) Replace the failing
microprocessor.
5.
(Trained service technician
only) Replace the microprocessor
board.
1.
Turn off the server and
disconnect it from power.
2.
(Trained service technician
only) Remove the
microprocessor from socket 2.
Note: The server will not
start when no microprocessor is
installed in socket 1.
3.
Reinstall the
microprocessor in socket 2 and
restart the server.
4.
(Trained service technician
only) Replace the failing
microprocessor.
5.
(Trained service technician
only) Replace the microprocessor
board.
Issue 02 (2011-05-25)

Advertisement

Table of Contents