Step 8 If you are instructed to return the SAS hard disk drive backplane assembly, follow all
packaging instructions, and use any packaging materials for shipping that are supplied to you.
----End
Replacing the SAS hard disk drive backplane assembly
To install the replacement SAS hard disk drive backplane assembly, complete the following
steps:
Step 1 Install the backplane onto the carrier.
1.
2.
Step 2 Slide the assembly into the card guides and pull the release tab toward the front of the server
to engage the assembly.
Step 3 Reconnect the SAS signal cable and SAS power cable to the backplane.
Step 4 Slide the hard disk drive backplane cable assembly into the server.
Step 5 Reinstall the hard disk drives and drive fillers.
Step 6 Install the top cover (see "Replacing the top cover").
Step 7 Connect the cables and power cords (see "Connecting the cables" for cabling instructions).
Step 8 Turn on all attached devices and the server.
Step 9 Restore the RAID configuration information that you backed up before you removed the hard
disk drive backplane.
----End
Issue 02 (2011-05-25)
Line up the notch on the backplane with the bottom-right corner of the carrier.
Push the backplane onto the carrier until it snaps into place.